1 00:00:00,256 --> 00:00:03,483 A detailed model earns its place by answering a project question. 2 00:00:04,096 --> 00:00:10,097 For SolidFEA, this introduction uses the Hong Kong FB6 and K7 case records. 3 00:00:10,572 --> 00:00:12,477 The two cases show why the geometry, 4 00:00:12,919 --> 00:00:17,314 load basis and interfaces must be reconciled before a result can support a 5 00:00:17,314 --> 00:00:19,943 design conclusion. For FB6, 6 00:00:20,386 --> 00:00:22,845 begin with the revised pile cap modelling brief. 7 00:00:23,430 --> 00:00:27,510 The newer geometry and material basis cannot inherit results from an older model 8 00:00:27,526 --> 00:00:29,942 without review. Record the drawing revision, 9 00:00:30,341 --> 00:00:33,185 cap geometry, pile locations and load cases. 10 00:00:33,775 --> 00:00:38,325 Keep concrete, steelwork, reinforcement and connection groups identifiable. 11 00:00:38,980 --> 00:00:44,170 For K7, the supplied November presentation includes steel frame and composite model views. 12 00:00:44,756 --> 00:00:46,362 Their colours identify components; 13 00:00:46,889 --> 00:00:48,282 they are not stress contours. 14 00:00:48,894 --> 00:00:52,292 The retained benchmark work also has its own solver and assumptions. 15 00:00:52,849 --> 00:00:54,156 Keep that provenance visible, 16 00:00:54,513 --> 00:00:59,020 rather than presenting every model image as a completed SolidFEA analysis. 17 00:00:59,633 --> 00:01:02,220 Both cases need a clear path from the applied actions 18 00:01:02,534 --> 00:01:04,055 through the assembly to the supports. 19 00:01:04,650 --> 00:01:06,128 Contact, separation, 20 00:01:06,612 --> 00:01:09,157 anchorage and connector behaviour can change that path. 21 00:01:09,556 --> 00:01:11,248 A reviewer needs equilibrium, 22 00:01:11,647 --> 00:01:14,234 mesh sensitivity and meaningful component forces, 23 00:01:14,762 --> 00:01:16,410 alongside any local stress plot. 24 00:01:16,834 --> 00:01:19,933 A numerical peak alone does not settle the engineering question. 25 00:01:20,546 --> 00:01:23,517 The AiXEK demonstration lets a member select a case, 26 00:01:23,916 --> 00:01:27,144 inspect its evidence status and prepare a focused review brief. 27 00:01:27,690 --> 00:01:31,344 New project results remain outstanding where the records do not establish them. 28 00:01:31,786 --> 00:01:34,544 The aim is a controlled comparison between calculations, 29 00:01:35,114 --> 00:01:39,920 model assumptions and supplied outputs, ready for a suitably qualified expert to review.